Previous   Next  

iii)  Project proponents shall monitor PM10, PM2.5, SO2, NOx, HCl, HCN in ambient air.Adequate pollution control measures shall be provided to control gaseous emissions.Scrubbers of more than 90 % efficiency shall be installed. Vents from scrubbers and condensers shall be periodically monitored and maintained as per the best practicable technology.

iv)  Cyanide content in the incinerator, flue gas and treated effluent shall be monitored regularly to meet the stipulations laid down by Gujarat Pollution Control Board (GPCB).HCN detectors should be provided in HCN, NaCN and Diphenyl Guanidire, (DPG) plant.

v)  All the storage tanks shall be under negative pressure to avoid any leakages. Closed handling systems for chemicals and solvents shall be provided. Magnetic seals shall be provided for pumps/agitators for reactors for reduction of fugitive emissions. Chilled brine based condensers shall be used to prevent emissions. Solvent traps shall be installed wherever necessary.

vi)  During transfer of materials, spillages shall be avoided and garland drains be constructed to avoid mixing of accidental spillages with domestic waste and storm drains.

vii)  Fugitive emissions in the work zone environment, product, raw materials storage area etc. shall be regularly monitored with instruments of proper range. The fugitive emissions shall conform to the standards prescribed by the GPCB.

viii)  The National Ambient Air Quality Emission Standards issued by the Ministry vide G.S.R. No. 826(E) dated 16th November, 2009 shall be followed.

ix)  The company shall upload the status of compliance of the stipulated environmental clearance conditions, including results of monitored data on its website and shall update the same periodically. It shall simultaneously be sent to the Regional office of MOEF,the respective Zonal office of CPCB and the State Pollution Control Board. The levels of SPM, RSPM, SO2, NOx and VOC (ambient levels) and HCl emissions from the stacks shall be monitored and displayed at a convenient location near the main gate of the
company and at important public places

x)  Total water requirement after expansion shall not exceed 615 m3/day. Total wastewater generation after expansion shall not exceed 258 m3/day. The level of Cyanide in the treated effluent shall not exceed 0.2 mg/l. The industrial effluent generation shall not exceed 258 m3/day.

xi)  All the effluent from all the sourced shall be processed for recovery/detoxification/recycling and then treated in the effluent treatment plant (ETP). The effluent containing Cyanide shall be treated properly. The treated effluent shall be disposed off in nearby Masma Khadi through pipeline only after meeting the norms prescribed under E (P)Rules or prescribed by the GPCB whichever is more stringent.

xii)  The company shall obtain Authorization for collection, storage and disposal of hazardous waste under the Hazardous Waste (Management, Handling and Trans-Boundary Movement) Rules, 2008 for management of Hazardous wastes and prior permission from GPCB shall be obtained for disposal of solid / hazardous waste in theTSDF.

 Page 4


Previous   Next